HP DC04 SAN Director Switch Hardware Reference Guide

5 Replacing DC04 SAN Director FRUs
This chapter provides information for replacing field-replaceable components.
IMPORTANT: The FRUs in the DC04 SAN Director can be removed and replaced without special
tools. The DC04 SAN Director can continue operating during many of the FRU replacements if the
conditions specified in the procedure are followed.
Replacing the chassis door
The chassis door must be installed to ensure that the DC04 SAN Director meets EMI and other
regulatory certifications. The replacement procedure for the chassis door takes less than 5 minutes.
Removing the chassis door
NOTE: The door is not hinged. It is installed straight on the chassis by snapping four ball studs
located on the chassis into receiving hardware on the door in the cabinet.
To remove the chassis door (see Figure 34 (page 65)):
1. Grip the side of the door. Support the door to prevent it from falling.
2. Gently pull the door straight out from the chassis until it snaps out of the ball studs on the
chassis.
Installing the chassis door
To install the chassis door (see Figure 34 (page 65)):
1. Align the holes in the door with the pins in the chassis.
2. Push the door into place.
Figure 34 Removing or replacing a chassis door
Replacing the vertical cable management assembly
The DC04 SAN Director is equipped with two vertical cable management finger assemblies. It can
continue to operate during the replacement of the cable management fingers. Due to the horizontal