HP DC04 SAN Director Switch Hardware Reference Guide
Table 9 Director and application blade LED descriptions (continued)
Recommended actionStatusColorLED purpose
No action requiredPort is online, with traffic flowing
through it.
Flickering green
Change the transceiver or reset
the switch from the workstation.
Transceiver or port is faulty.Fast-flashing amber (on
1/4 second, then off
1/4 second)
Verify that the power LED is on;
verify the transceiver and cable.
Port is offline.No light (LED is off)10-GbE Port Status
(FCOE10-24)
No action requiredPort is online but has no traffic.Steady green
No action requiredPort is online, with traffic flowing
through port.
Flickering green
Reset the port by doing a
shutdown and no shutdown
sequence from a cmsh session.
Port is receiving light but is not
online yet.
Steady amber
Enable the port by issuing the
shutdown command from a
cmsh session.
1
Port is disabled.Slow-flashing amber (on
2 seconds, then off 2
seconds)
Change the transceiver or reset
the port by issuing a shutdown
Transceiver or port is faulty.Fast-flashing amber (on
1/4 second, then off
1/4 second)
and no shutdown sequence
from a cmsh session.
1
For more information on the CEE Management Shell (cmsh), see the Fabric OS Command Reference Manual or the
Converged Enhanced Ethernet Command Reference.
Monitoring Director blade status 57