HP DC SAN Backbone Director Switch Hardware Reference Guide

1. Observe the LED indicators on the WWN bezel and verify that they reflect the actual status
of the components. The WWN bezel covers the WWN cards and allows its LEDs to shine
through. The LEDs on the WWN bezel provide a consolidated view of the port, CP, and CR
blade status (see Table 14 (page 80)).
If a blade slot has a filler panel installed, the corresponding LEDs on the WWN card do not
illuminate.
Table 14 WWN LED patterns
Recommended actionStatusColorLED location/purpose
No action requiredPower is on.Steady greenDirector blade/CP/CR
blade power
Verify card.Card is faulty.Steady amberDirector blade/CP/CR
blade status
No action requiredCard is functioning.No light (LED is off)
NOTE: If a status LED on the WWN bezel flashes, the power LED on the WWN bezel also
flashes, for increased visibility.
2. Verify the WWN card status using the commands listed in Table 15 (page 80). Difficulty
retrieving or modifying this data could indicate a WWN card failure.
Table 15 Commands identifying the WWN card status
CommandsWWN card information
wwn, chassisShowWWN values
chassisShowData about the chassis and WWN card
ipAddrShow, ipAddrSetEthernet and FC IP address information for the CP blades
historyShow, historyLastShowHistory log information
switchNameName of switch
chassisNameName of chassis
3. Look up the error message indicating the status of the WWN unit (see Table 16 (page 80)).
Enter the chassisShow command to determine the status of the WWN unit.
Table 16 WWN card related system log messages
System message (errshow or errdump)Type of message
<timestamp>, [EM-1050],
<sequence-number>,, INFO, <system-name>,
FRU WWN # removal detected.
WWN unit removal was detected
<timestamp>, [EM-1049],
<sequence-number>,, INFO, <system-name>,
FRU WWN # insertion detected.
WWN unit insertion was detected
<timestamp>, [EM-1004],
<sequence-number>,, CRITICAL,
<system-name>, WWN # failed to power on
WWN unit fails to power on
<timestamp>, [EM-1034],
<sequence-number>,, ERROR, <system-name>,
WWN # set to faulty, rc=<return code>
WWN unit is being faulted
80 Replacing DC SAN Director FRUs