HP DC SAN Backbone Director Switch Hardware Reference Guide

At 120 VAC, four power supplies are required when using the FR4-18i blade.
Two redundant WWN cards on the non-port side, to maintain chassis-specific information
such as WWNs, IP addresses, and summary status information for each Director blade
and power supply through LEDs
4-Gb and 8-Gb SFP optical transceivers (4-Gb SFPs operate at 1 Gb, 2 Gb, or 4 Gb.
8-Gb SFPs operate at 2 Gb, 4 Gb, or 8 Gb.)
XFP optical transceivers (10-Gb/s)
10-Gb SFP optical transceivers
All blades are serviced from the port side of the DC SAN Director. Blowers, power supplies,
and power cables are serviced from the non-port side.
Improved cable management using a re-designed cable management comb and chassis door.
Constant intake and FRU temperature monitoring.
Redundant AC primary power connections to ensure high availability. Each power supply has
its own connector. Therefore, the number of primary power connections varies from two to
four.
Port side of the DC SAN Director
NOTE: Airflow in the DC SAN Director is from the non-port (non-cable) side to the port (cable)
side and out the exhaust vent.
Figure 1 (page 9) shows a sample configuration of the port side of the DC SAN Director.
8 DC SAN Director overview