Table 25 Typical power supply requirements for the HP SN8000B 8-Slot SAN Director (continued)
Comments
@200-240 VAC
nl
(redundant
configuration)
@110 VAC
nl
(redundant
configuration)TypeBlade
200-240VAC: 1+1 power
supplies
nl
Two power suppliesFour power suppliesPort/
Intelligent
blade
FC16-32,
nl
FC16-48
nl
FX8-24
nl
110VAC: 2+2
1
power
supplies
nl
FS8-18
nl
192 16Gb Ports & max. 2
intelligent blades (FX8-24
Max. four FC16-48 port
blades and max. 2 Intelligent
blades
/FS8- 18/combination) with
QSFP ICLs
200–240 VAC: 1+1 power
supplies
nl
Two power suppliesFour power suppliesPort/
Intelligent
blade
FC8-32E
nl
FC8-48E
nl
FX8–24
nl
110 VAC: 2+2
1
power
supplies
nl
FS8–18
nl
Max. four FC8-48E port
blades and max. 2 Intelligent
blades
192 8Gb Ports & max. 2
intelligent blades (FX8-24
/FS8-18/ combination) with
QSFP ICLs
200-240VAC: 1+1 power
supplies
nl
Two power suppliesFour power suppliesPort bladeFC16-48
nl
(Maximum of seven
FC16-48 blades, with one
empty port blade slot)
nl
110VAC: 2+2
1
power
supplies
nl
Max. 7 FC16-48 port blades
200-240VAC: 1+1 power
supplies
nl
Two power suppliesFour power suppliesPort bladeFC8-48E
nl
(Maximum of seven FC8-48E
blades, with one empty port
blade slot)
nl
110VAC: 2+2
1
power
supplies
nl
336 8Gb ports + QSFP ICLs
nl
Max. 7 FC8-48E port blades
200-240VAC:
nl
Four power suppliesNot supportedPort bladeFC16-32
nl
For DCX 8510-8, four (2+2)
1
nl
FC16-48
nl
384 16Gb ports + QSFP
ICLs
220V AC power supplies are
required
200-240VAC:
nl
Four power suppliesNot supportedPort bladeFC8-32E
nl
For DCX 8510-8, four (2+2)
1
nl
FC8-48E
nl
(384 8Gb ports + QSFP
ICLs)
220V AC power supplies are
required
For DCX 8510-8, four (2+2)
1
nl
Four power suppliesNot supportedIntelligent
blade/
Combination
FC16-32, FC16-48,
nl
FC8-64, FC8-32E,
nl
FC8-48E, FS8-18,
nl
220V AC power supplies are
required when any special
purpose blades are installed
FX8-24
nl
(Any combination of 8Gb or
16Gb ports and intelligent
blades with QSFP ICLs)
nl
1
When 2+2 power supply combination is used, the users are advised to configure the Fabric Watch setting for switch
marginal state to be two power supplies. Users can use the CLI switchstatuspolicyset to configure this value if
the current value is set to zero. In FOS v7.0.x, the default setting for the marginal state, due to missing power supplies,
is incorrectly set to zero (Defect 000349586). This will prevent Fabric Watch from generating notifications when the
switch enters the marginal state due to missing power supplies.
Power cords
The power cords provided with the DC SAN Director are specific to the country where it is installed.
For each of these types of power cords (see Table 26 (page 107)), the end that connects to the
Director chassis has an IEC 60320/C19 cable connector. The two AC power receptacles on each
chassis are equipped with IEC 60320/C20 power connectors.
106 Technical specifications