HP Data Protector software interaction with deduplication enabled replication

13
queue.file= C:/Program
Files/OmniBack/automated_replicated_media_import/queue/D2D_import.queue
defines the path and the name of the queue file. You may want to choose a queue file name
that matches your naming convention. Multiple queue files might be generated that will be used
to import cartridges.
log.level=4
defines the granularity of logging. There exist five logging levels. Choose logging level two or
three for troubleshooting purposes. If the setup runs successfully, you may consider switching to
logging level four, which creates log files best formatted for reporting purposes.
log.file= C:/Program
Files/OmniBack/automated_replicated_media_import/D2D_VLS_rep_log.txt
defines the path and the name of the log file. You may choose a log file name that matches
your naming convention. The log file is a tab-separated log file. The content can be imported
into a spreadsheet application for further log file data handling such as generating cartridge
import reports.You may select a common log file in all your configuration files or specify
individual files to group per import devices.
log.truncate.period=7
defines the period in days after which the log file will be truncated. The truncation will start at
midnight. Specifying zero (0) will never truncate the log file. The truncation will only happen
when the import script
executeImportTasks.pl is running.
report.file=C:/Program Files/
OmniBack/automated_replicated_media_import/report.txt
defines the path and the file name of the (replication and import) status report.
dp.home.directory=C:/Program Files/OmniBack
is an optional parameter you can set to specify the home directory for the import script
package. Use this parameter in case the HP Data Protector install path gathering of the scripts
has errors.
specify your library settings
in the bottom section of the configuration file you have to specify:
the names of the virtual libraries as they are configured on the target library
the time window in which it is permitted to import cartridges
the drive name as it is configured for the target device configuration in the Data Protector cell
on which you plan to import cartridges.
For example:
WP_Library 2_Target/00:00-00:00/D2D_Target_1_tpc245
specifies a library on a D2D device as it appears on the configuration web page of the device.
No time slot is specified in which to import cartridges, which means import is permitted at the
next scheduled or manually triggered cartridge import task. The last entry in the configuration
line specifies the name of the tape drive device as it is configured on the Data Protector Cell
Manager.
References to a library configured on a VLS need to be entered similar to the following:
01Ub7cHI0n/00:00-00:00/VTL_SCSI_1_Rep_Target_tpc209|VTL_SCSI_2_Rep_Target_tpc209
Note: For the VLS device configuration you need to enter the device serial number rather than
the library device name.
You may specify multiple tape drive devices to import cartridges. Multiple tape drives for the
cartridge import need to be separated by |.