HP Data Protector Software Cell Manager Failover Process (standby Cell Manager)

8
Figure 6.
2. Modify the following parameters in the global options file on the production Cell Manager
(site(A)).
ScriptOutputTimeOut=600
This was increased to 600 minutes to allow enough time for the “dp_database1-pre.bat” script to
complete.
Note
# ScriptOutputTimeout=TimeoutInMinutes
# default: 15 minutes
# This timeout is used by the Backup SM. The session pre-exec
# or post-exec script should send some output at least every
# ScriptOutputTimeout minutes, or the session gets aborted by
# the Session Manager
FileMediumCapacity=10240
Note
# FileMediumCapacity=MaxSizeInMBytes
# default: 100
# If you are using "file" devices, you should change this to
# specify the maximum size of a ”file” medium. When Data Protector
# writes specified size of data in one file, you will get a
# mount prompt. Or if you are using "file” exchanger, the next
# "file medium” will be loaded. If the global option is
# changed, the logical medium must be exported and the file
# removed before initialization. Otherwise the original size
# will be used.