HP Data Protector Software Cell Manager Failover Process (standby Cell Manager)
5
Patches
Be sure to have the same patch level on either Cell Manager host. Figure 3 illustrates a sample patch
list off a Cell Manager running on Windows 2003 Server.
Figure 3.
Configuration
The following tasks apply to the newly installed standby Cell Manager on Windows 2003 Server.
1. Stop Data Protector services on standby Cell Manager.
Open a Windows command box and type:
D:\Program Files\Omniback\bin\omnisv –stop
2. Copy the contents of the IDB and configuration directories to a save location in case they are
required in the future.
D:\Program Files\Omniback\config\ -> D:\Save\config\
D:\Program Files\Omniback\db40\ -> D:\Save\db40\
3. Change the following registry key value from the FQDN of the standby Cell Manager to that of the
production Cell Manager.
Note
Manipulating the registry file of the operating system requires special
care.
My Computer\HKEY_LOCAL_MACHINE\\SOFTWARE\Hewlett-Packard\Open
View\Omniback\Site\CellServer