HP Data Protector MOM Configuration and Troubleshooting Guide

18 | P a g e
Prerequisites
Check that the Data Protector Cell Managers in all cells have the same version of Data
Protector installed and running.
Check that there are no backup, restore, or media management sessions running on any of the
cells to be added to the CMMDB.
Overview
There are two stages to configuration:
Configure CMMDB on the MoM Manager.
Configure CMMDB on each client cell.
1. Configuring CMMDB on the MoM Manager
1. Run a backup of the IDB.
Alternatively, log on to the MoM Manager and copy the following directory to a temporary
location for safety reasons:
On Windows Server 2008: Data_Protector_program_data\db40\datafiles\mmdb
On other Windows systems: Data_Protector_home\db40\datafiles\mmdb
On UNIX systems: /var/opt/omni/server/db40/datafiles/mmdb
2. On the MoM server, run the following command to merge the local MMDB into the CMMDB:
On Windows systems:
Data_Protector_home\bin\omnidbutil -mergemmdb Cell_Server_Hostname
On UNIX systems: /opt/omni/sbin/omnidbutil -mergemmdb Cell_Server_Hostname