D3000 Disk Enclosure MSG (734754-001, March 2014)
Recommended ActionError DetailError CodeError Type
Failure in one or more
rotors of Fan module 1
E9 1. If a fan module has an amber LED indication, try
reinserting it.
2. If none of the fans have an amber LED, replace one
fan module and wait 30 seconds.
Failure in one or more
rotors of Fan module 2
EA
3. If the error persists, then check for new firmware
releases and upgrade the enclosure firmware. New
firmware versions, containing new features and defect
fixes, are released periodically.
4. If the error persists, contact an HP representative, a
fan module replacement may be necessary.
Permanent error in Fan
modules I2C bus
E4Fan Module
Communication
Error
1. Remove and reinsert each fan module in turn.
2. If this does not resolve the issue, then remove and
reinsert the I/O module that shows the status code.
Communication error
with Fan module 1
E5
3. If the error persists, then check for new firmware
releases and upgrade the enclosure firmware. New
Communication error
with Fan module 2
E6
firmware versions, containing new features and defect
fixes, are released periodically.
4. If the error persists, contact an HP representative, a
fan module replacement may be necessary.
I/O module error codes 39