HP StoreOnce B6200 Maintenance and Service Guide (February, 2014)
Firmware revision
It should not be necessary to update the firmware if you are replacing a component only. Any
firmware updates that apply to the P2000 controller or JBOD are automatically applied whenever
there is a new release of the HP StoreOnce B6200 Backup System software (which includes
firmware updates).
HP B6200 storage controller array (one for each server node)
There is a storage controller array with twelve SAS storage disks connected to each server node.
Figure 8 Front view of the storage controller array
2 Disk drive Fault/UID LED1 Enclosure ID LED
4 Fault ID LED3 Disk drive Online/Activity LED
6 Heartbeat ID LED5 Unit Identification (UID) LED
Figure 9 Rear view of the storage controller array
2. Power sockets1. Fans
3, 4, 5 and 6. SAS IN ports from the two server nodes (see P2000 controller and JBOD cabling (page 34).
8. iLO3 port to internal network switch7. Serial port for service support
10. SAS OUT ports (connect to P2000 JBODs)9. Service port
Rear view of the capacity upgrade kit
A capacity upgrade kit consists of a pair of 12–disk storage expansion arrays that are connected
to the storage controller arrays. SAS cables are included in the capacity upgrade kits. See also
the installation poster supplied with the Capacity Upgrade kit.
Firmware revision 33