HP StoreOnce B6200 Maintenance and Service Guide (February, 2014)

Table 4 Internal network static IP addresses (continued)
Network switches
AddressPort/ComponentDeviceAddressPort/ComponentDevice
10.154.4.5bond0Node 510.154.4.1bond0Node 1
10.154.5.5iLONode 510.154.5.1iLONode 1
10.154.4.6bond0Node 610.154.4.2bond0Node 2
10.154.5.6iLONode 610.154.5.2iLONode 2
10.154.2.5Controller AFirst P2000 shelf10.154.2.1Controller AFirst P2000
shelf
10.154.3.5Controller BFirst P2000 shelf10.154.3.1Controller BFirst P2000
shelf
10.154.2.6Controller ASecond P2000
shelf
10.154.2.2Controller ASecond P2000
shelf
10.154.3.6Controller BSecond P2000
shelf
10.154.3.2Controller BSecond P2000
shelf
How are hardware problems notified?
As long as emails and/or SNMP have been enabled and configured correctly, hardware problems
are notified as alerts.
1. If you receive an alert that relates to a hardware problem, you should first look at the Hardware
Problem Report on the GUI.
Figure 2 Hardware Problem Report (GUI)
Alternatively, use the two StoreOnce CLI commands:
hardware show problems: to return the same information displayed in the Hardware
Problem Report from the StoreOnce GUI
hardware show status detail to drill down further into the detail
2. Select the problem in the list and click Details for more information about the hardware
component.
18 Pre-requisites