HP StoreOnce Backup System Linux and UNIX Configuration Guide (BB852-90952)
The response will be:
Target address “x.x.x.x:3260,1” has been successfully added.
4. To display the discovery target that has been configured, type the following:
# iscsiutil –pD
The output will be similar to this:
Discovery Target Information
----------------------------
Target # 1
-----------
IP Address : x.x.x.x
iSCSI TCP Port : 3260
iSCSI Portal Group Tag : 1
User Configured:
----------------
Authenticaton Method :
CHAP Method : CHAP_UNI
Initiator CHAP Name :
CHAP Secret :
Header Digest : None,CRC32C (default)
Data Digest : None,CRC32C (default)
5. To discover operational target devices, type the following:
# ioscan -H 255
The output will be similar to this:
H/W Path Class Description
==================================================
255/0 iscsi iSCSI Virtual Node
255/0/0.0 ext_bus iSCSI-SCSI Protocol Interface
255/0/0.0.0 target
255/0/0.0.0.0 tape HP Ultrium 3-SCSI
255/0/2.0 ext_bus iSCSI-SCSI Protocol Interface
255/0/2.0.0 target
255/0/2.0.0.0 autoch HP MSL G3 Series
6. To display operational target devices, type:
# iscsiutil –pO
The output will be similar to this:
Operational Target Information
------------------------------
Target # 1
-----------
Target Name : iqn.1986-
03.com.hp:storage.d2d.cr209107ff.500110a6656e596f.library1
.drive1
Target Alias :
No. of Target Addresses : 1
Target Address # 1
-------------------
IP Address : x.x.x.x
iSCSI TCP Port : 3260
iSCSI Portal Group Tag : 1
User Configured:
----------------
Authenticaton Method :
CHAP Method : CHAP_UNI
Initiator CHAP Name :
CHAP Secret :
Header Digest : None,CRC32C (default)
Data Digest : None,CRC32C (default)
Target # 2
-----------
18 HP-UX 11i v2/v3 (PA-RISC & IA64)