HP StoreOnce B6200 Maintenance and Service Guide (February, 2014)

IP address = the internal network address of the P2000 controller where the HDDs that
you wish to update are situated
User Name = admin
Password = !admin
NOTE: You can also use the command line option:
cp019925_Muskie_0008.exe /target <IP> /user admin /passwd !admin
Where <IP> is the internal network address of the P2000 controller where the HDDs that you
wish to update are situated.
8. At the end of the process, the executable will give feedback on successful’ / unsuccessful’
updates. To check, login to the P2000 controller using puTTY, and use the P2000 command
show disks. Look at the SP Health column. If it is not OK, a Health Reason will be given.:
# show disks
Location Serial Number Vendor Rev How Used Type Size Rate*(Gb/s) SP Health
Health Reason
----------------------------------------------------------------------------------------------------------------------------
1.1 9WK2MD0Q0000C117C64G SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
1.2 9WK2YFTC00009124TT4Q SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
1.3 9WK2MK8V00009118T9HE SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
1.4 9WK2MD4H00009119HKZM SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
1.5 9WK2MKQ900009120MC2P SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
1.6 9WK2MKCH00009118VG37 SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
1.7 9WK2MHCH00009118W8LS SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
1.8 9WK2MCLZ0000C11712AW SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
1.9 9WK52D5Z000091520W6K SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
1.10 9WK2MCQ200009119Z0MM SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
1.11 9WK2MKWC00009118VBAW SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
1.12 9WK2MC2R00009119MB4F SEAGATE 0008 VDISK SAS 1000.2GB 6.0 OK
----------------------------------------------------------------------------------------------------------------------------
9. Power on the nodes within the couplet, using the power button on the server.
10. Login to the GUI using the management VIF (10.154.1.1), and wait for the Service Sets to
show a status of Running.
NOTE: If you used the hardware poweroff <nodeX> command, the Service Set may
stay in the ‘initialising state for a while (possibly longer than 1 hour). Please do not reboot
the nodes during this time.
11. Login to the StoreOnce CLI using the management VIF (10.154.1.1), and enable failure using
the StoreOnce CLI command:
hardware enable failover
12. The process is now complete.
32 Maintaining P2000/MSA Array Controller components