hardware update firmware
Description of Command Function
Updates the firmware for the defined hardware type.
Command Syntax
hardware update firmware <nodeX|storageX|switchX> [force] [user]
[password]
Command Authority
Administrator
Command Object Requirements
Not applicable no objects exist within this command.
Command Parameter Requirements
NODE
X
This optional parameter is used to define an individual file server node. X is a
unique numeric index defining the hardware component. It is assigned during the initial
automatic hardware initialization and configuration, and its value resides in the node_config
file. A complete list of NODEX labels can be obtained using the hardware show node
status command (see “hardware show node status (page 80)).
NOTE: X is for multi-node products only. Use NODE without defining X for single-node
products.
storage
X
This optional parameter is used to define an individual storage array. X is a unique
numeric index uniquely defining the hardware component. Use odd numbers (1, 3, 5, etc.),
and it updates the partner nodes (2, 4, 6, etc.) as well.
NOTE: X is for multi-node products only; use storage without defining X for single-node
products.
switch
X
This optional parameter is used to define an individual switch. Use this from a node
in the cluster, and it flashes all switches in the cluster.
NOTE: This parameter is for multi-node products only.
force This optional parameter forces firmware actions regardless of flash recommendations.
This parameter is typically used when downgrading the firmware.
user This is the user name for flashing switches and is only required for a switch configured
with different credentials.
password This is the password for flashing switches and is only required for a switch
configured with different credentials.
Requirements for Command Execution
The command entry must conform to command syntax.
All parameter values must be valid. See parameter requirements for details.
Successful Command Output
Upon successful completion of the command, the firmware for a defined hardware type is updated.
Command Operation during Abnormal Conditions
If the command does not conform to the required syntax, the following is displayed:
Command Failed - the command does not conform to the required syntax,
SYNTAX, where SYNTAX is the command syntax as described under Command Syntax in this
section.