HP StoreOnce Backup System CLI Reference Guide
hardware show status
Description of Command Function
Provides a status on all hardware components in the StoreOnce system.
Command Syntax
hardware show status [detail] [dev-id]
Command Authority
Operator and Administrator
Command Object Requirements
Not applicable – no objects exist within this command.
Command Parameter Requirements
• detail – This optional parameter provides a detailed output for the hardware components
selected. If not defined, only the device ID and its status are provided.
• dev-id – This optional parameter selects a particular device and its immediate children and
then shows their status. If not defined, the top level status and device IDs of couplets (with their
nodes and storage arrays) and internal network switches are shown. Find the device ID of
any component by using the hardware show status command and then using that device’s
ID with the same command to view the device IDs of its subcomponents.
Requirements for Command Execution
• The command entry must conform to command syntax.
• All parameter values must be valid. See the parameter requirements for details.
Successful Command Output
Upon successful completion of the command, the status of selected devices is shown.
NOTE: If CLI paging is enabled, the output of this command is displayed with paging.
Command Operation during Abnormal Conditions
If any of the command execution requirements fail, command execution terminates, the hardware
status is not displayed, and one of these error messages is displayed:
• Command Failed - the command does not conform to the required syntax,
SYNTAX, where SYNTAX is the command syntax as described under Command Syntax in this
section.
• Command Failed – Component for the device ID does not exist in system
Examples
Status of all devices:
# hardware show status
Name Dev-id Status
--------------------- ------------------------------------ ------
ab12cd3efgh0-1 12345678-1111-2222-4533-35304D4C4E45 OK
ab12cd3efgh0-2 12345678-2222-3333-3233-323430334452 OK
p1228 Storage System 12f34567-3333-1000-b007-533556303541 FAILED
p1228 Storage System 0123456f-0000-1000-b000-533457303132 FAILED
HP 5920AF-24XG Switch switch1 OK
HP 5920AF-24XG Switch switch2 OK
82 Alphabetical List of Commands and Details