HP StoreOnce Backup System CLI Reference Guide
Successful Command Output
Upon successful completion of the command, the following message is displayed, and then the
CLI user prompt is displayed.
Warning – Any data on the cartridge(s) will be lost, continue? (y/n)
A “y” response must be entered for command execution to continue.
Command Successful
Command Operation during Abnormal Conditions
• If any of the command execution requirements shown in Successful Command Output fail,
command execution terminates, the cartridge is not deleted, and one of the following error
messages is displayed.
◦ Command Failed – Did not conform to the correct command syntax
“vtl delete cartridge [SETX] LIBX [{CARTX | ALL}] [barcode
<string>] [mail <num>] [ slot <num> ]”
◦ Command Failed – The service set <SETX> is invalid
◦ Command Failed – The service set <SETX> does not exist
◦ Command Failed – The library <LIBX> is invalid
◦ Command Failed – The library <LIBX> does not exist
◦ Command Failed – The cartridge(s) to be deleted was not defined
◦ Command Failed – The cartridge <CARTX> does not exist
◦ Command Failed – The mail slot <mail> does not exist in the
library
◦ Command Failed – The slot <slot> does not exist in the library
◦ Command Failed – The mail slot <mail> does not contain a cartridge
◦ Command Failed – The slot <slot> does not contain a cartridge
◦ Command Failed – The barcode is invalid
◦ Command Failed – The barcode string must consist of 8 alphanumeric
characters
◦ Command Failed – A cartridge with barcode <barcode> does not
exist in the library
◦ Command Failed - Cannot perform operation as slot is in
replication target mapping
• If the user does not respond to the warning message with y, the command terminates, and
the CLI returns to the user prompt.
Example
# vtl erase cartridge LIB1 slot 3
Command Successful
234 Alphabetical List of Commands and Details