HP StoreOnce Backup System CLI Reference Guide
Command Operation during Abnormal Conditions
• If any of the shown in Successful Command Output command execution requirements fail,
command execution terminates, the cartridge is not deleted, and the appropriate error message
listed below is displayed.
◦ Command Failed – Did not conform to the correct command syntax
“vtl delete cartridge [SETX] LIBX [{CARTX | ALL}] [barcode
<string>] [mail <num>] [ slot <num> ]”
◦ Command Failed – The service set <SETX> is invalid
◦ Command Failed – The service set <SETX> does not exist
◦ Command Failed – The library <LIBX> is invalid
◦ Command Failed – The library <LIBX> does not exist
◦ Command Failed - Cannot perform operation as slot is in
replication target mapping
◦ Command Failed - Invalid slot range selector
• If the user does not respond to the warning message with y, the command terminates, and
the CLI returns to the user prompt.
Example
# vtl erase cartridges LIB1 from SLOT1 to SLOT8
Command Successful
vtl delete cartridges 229