HP StorageWorks D2D Backup System Release Notes (EH880-90963, February 2008)

Fixes
Firmware in attached tape drives can be updated.
Prerequisites
Requires Microsoft Internet Explorer 6.x or higher or Mozilla Firefox 1.5 or 2.x.
Installation instructions
NOTE:
During the update the HP D2D Backup System will reboot. After the update all conguration settings
on the HP D2D Ba
ckup System will be retained.
1. Save the rmware image le on a server or PC that is connected to the same subnet as the HP
D2D Backup System.
2. From a Web Browser, launch the HP StorageWorks D2D Backup System Web Management Interface
by typing in the IP address of the HP D2D Backup System to be updated.
3. Ensure that there are no current or scheduled backup jobs that will occur during the rmware update
period, because the HP D2D Backup System will reboot during the update process.
4. Log in and navigate to the Firmware Page.
5. Select the Browse button in order to locate the rmware image on the host system.
6. Select Upload update the rmware.
NOTE:
Do NOT navigate away from the rmware page.
7. The LEDs on the HP D2D Backup System will ash a rmware update pattern (alternate amber
and green).
8. After a few seconds the HP D2D Backup System will reboot, completion of the reboot is indicated by
all LEDs returning to current system status (generally all green).
9. Reconnect to the Web Management interface to observe that the upgrade has completed successfully.
10. Manually log back on to the HP D2D Backup System iSCSI targets via the iSCSI initiator from each
system. Use the HP D2D Backup System as a backup target. Alternatively, if targets have been made
persistent (restore automatically on reboot), simply reboot the host systems.
11 . To make use of new autoloader functionality any previously congured autoloaders should have
their emulation type changed to the new HP 1x8 G2 Autoloader emulation. To do this, use the
devices page from the web management interface.
Dete
rmining current version
From
a Web Browser, launch the HP StorageWorks D2D Backup System Web Management Interface
by ty
ping in the IP address of the HP D2D Backup System to be updated. Navigate to the Firmware
Pag
e which displays the current rmware version.
Effective date
February 11, 2008
4