HP D2220sb Storage Blade Maintenance and Service Guide
Removal and replacement procedures 37
10.
Install the storage blade.
11. Power up the partner server blade.
After you replace the system board, you must re-enter the product identification and serial number in the
Onboard Administrator using the command line. The Onboard Administrator CLI can be accessed locally
from a laptop connected to a serial port connector on the rear of the Onboard Administrator module or
remotely through a Telnet or SSH session.
To enter the product information:
1. Obtain the serial number from the product information tag.
2. Access the Onboard Administrator CLI.
3. Issue the following command in the CLI:
SET DEVICE SERIAL_NUMBER BLADE <bay number> <serial number>
Drive drawer
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the D2220sb before
beginning any installation procedure. Improper grounding can cause ESD.
CAUTION: Do not operate the D2220sb with the access panel open or removed. Operating the
D2220sb in this manner results in improper airflow and improper cooling that can lead to thermal
damage.
CAUTION: If the pass-through board and cable are not removed before removing the drive
drawer, then damage could occur to the drive drawer, cable, and controller board.
To remove the component:
1. Back up all data on the D2220sb.
2. Power down the partner server blade (on page 21).
3. Remove the D2220sb (on page 21).
4. Remove all drives ("Remove the drives" on page 23).
5. Remove the access panel (on page 26).