Removal and replacement procedures 33
4.
Tilt the LED panel away from the front of the storage blade until the retaining clips are clear of the back
of the LED panel, and then remove the LED panel.
To replace the component, reverse the removal procedure.
System board
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server blade
before beginning any installation procedure. Improper grounding can cause ESD.
CAUTION: Do not operate the storage blade with the access panel open or removed. Operating
the storage blade in this manner results in improper airflow and improper cooling that can lead
to thermal damage.
To remove the component:
1. Back up all data on the storage blade.
2. Power down the partner server blade (on page 22).
3. Remove the storage blade (on page 22).
4. Remove all drives ("Remove the drives" on page 24).
5. Remove the access panel (on page 26).
6. Remove the FBWC capacitor pack ("FBWC capacitor pack" on page 29).
7. Remove the FBWC module ("FBWC module" on page 30).