HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

Explanation and recommended actionsMessage textMessage ID
The load module identified by load-module-name cannot be found.
BCM Monitor will stop.
Check whether the load module has been properly installed.
Module not found: load-module-
name.
YK8010E CON
The STGADMIN.YKA.BCM.YKQUERY profile or the
STGADMIN.YKA.BCM.COMMANDS profile is not defined in the
FACILITY class of RACF.
Review the RACF settings, and then restart BCM Monitor.
xxxxxxxx
Maintenance information
The profile is not defined in the facil-
ity class of RACF: xxxxxxxx.
YK8011E CON
The specified prefix prefix-name is being used by another program.
Review the YKMONCG file.
The specified prefix is being used by
another program: prefix-name.
YK8012E CON
BCM Monitor terminated abnormally.
If you cannot determine the cause of this problem, obtain an ABEND
dump in SYSABEND dump format, and then make a request to the
Support Center to investigate the problem.
BCM Monitor abended.YK8013E CON
BCM Monitor accepted the MODIFYcommand-name command.
MODIFY command accepted: com-
mand-name.
YK8014I CON
BCM Monitor accepted the STOP command.
STOP command accepted.YK8015I CON
There is an error in the command syntax.
Make sure that the entered command is valid.
Command syntax error.YK8016E CON
There is an error in the command-name command.
Make sure that the entered command is valid.
Invalid command: command-name.
YK8017E CON
There is an error in an operand of the command-name command.
Correct the operand, and then re-enter the command.
Operand is incorrect: command-
name.
YK8018E CON
An attempt to execute the command identified by command-name
failed because the number of commands waiting to be executed has
reached the upper limit.
Wait until all the waiting commands are finished executing, and then
re-execute the command.
The number of commands of execu-
tion waiting exceed the upper limit:
command-name.
YK8019E CON
Information is displayed for the command waiting to be executed.
nn
Number assigned to the waiting command
command-name
Name of the waiting command
The full name of the command is displayed, even if the abbreviated
name of the command was entered.
parameter
Parameter specified in the waiting command
The full name of the parameter is displayed, even if the abbreviated
name of the parameter was specified. If an omittable parameter
was omitted, the default value is displayed.
nn: command-name[ parameter].
YK8020I CON