Type of error
Error details
Error
code
OtherSMARTPATHCMDCAJCAACABC
NNNNYNNN
The CAJ ATTIME suspend time cannot be set. The
reason might be one of the following:
• The specified time is earlier than the consist-
ency time.
• The timer type remains Local because the
CAJ copy pair has not been resynchronized
after the timer type was changed from Local
to System.
When changing the timer type from Local to
System, you need to suspend the CAJ copy pair.
If the CAJ ATTIME suspend time has already been
set, perform the following procedure to set the CAJ
ATTIME suspend time again.
1. Suspend the CAJ copy pair.
2. Change the timer type.
3. Resynchronize the CAJ copy pair.
4. Set the CAJ ATTIME suspend time again.
466A
NNNNYNNN
The CAJ ATTIME suspend time cannot be set be-
cause the C/T group ID of the specified BC copy
pair is incorrect.
466B
NNNNYNNN
The CAJ ATTIME suspend time cannot be set be-
cause power-off processing is in progress.
4672
NNNNYNNN
The CAJ ATTIME suspend time cannot be set for
the following reasons:
• The specified volume is not part of a BC copy
pair.
• The specified C/T group does not contain a
BC copy pair that contains the specified
volume.
• The specified C/T group is not used by a BC
copy pair created with BC Manager.
4678
NNNNYNNN
The NORMAL ATTIME suspend time cannot be set
because the CAJ ATTIME suspend time has already
been set for the specified BC C/T group.
467A
NNNNYNNN
The CAJ ATTIME suspend time cannot be set be-
cause the NORMAL ATTIME suspend time has
already been set for the specified BC C/T group.
467B
NNNNYNNN
The CAJ ATTIME suspend time cannot be set be-
cause a copy pair that is not in the Duplex status
is included in the specified BC C/T group.
467C
NNNNYNNN
A BC copy pair cannot be made, resynchronized,
or suspended because the CAJ ATTIME suspend
time has been set for the specified BC C/T group.
4681
Storage system sense byte information238