HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

<route>: Route list ID
<route-label>: Route label
<cgmonstat>: Copy group monitoring status (ACTIVE or INACTIVE)
<cgsastat>: Copy group startup status to be checked for starting BCM Monitor
<cgsaact>: Startup action executed if the copy pair status for starting BCM Monitor is different from
the specified startup status
<cgsaopt>: Option information of the CGSTARTUPSTATUS parameter
<status> <action><err-action>:
Status, action, and error action for the copy group specified in STATUS and ACTION
These parameters appear a specified number of times.
Identifying the volume to be processed
The volume to be processed is determined by the copy group number and copy pair number output
in a message as follows.
Identifying the volume serial number from the REXX script
Display the following STEM variable.
stem-name.CopyGroup.copy-group-number.Pair.copy-pair-number.Volser
Identifying the volume serial number from the configuration file
Use the following steps to acquire the volume serial number from the configuration file:
1. Count the CopyGroupContainer tags from the beginning of the file and identify the CopyGroup-
Container tag.
2. From the identified CopyGroupContainer tag, count the CopyPair tags from the beginning of the
file and identify the CopyPair tag.
3. The SerialNum under the identified CopyPair tag is the volume serial number to be processed.
User completion codes
The following table provides details about the user completion codes.
Table 47 User completion codes
ExplanationCompletion codes
There is a problem with the issued CCW.
The version of the registered user SVC might be old. Check whether the latest user SVC is registered by
performing the following operations:
• Using a CLI command:
Execute the YKINSCHK command, and check that OK is displayed for User SVC Routine.
• From the ISPF panel:
From the Installation Verification Summary panel, check that OK is displayed for User SVC Routine.
U0003
Messages218