HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

Explanation and recommended actionsMessage textMessage ID
A path-controlled storage system does not support path group IDs (path
IDs for which values other than 00 are specified). Revise the definition
associated with whether the storage system can use path group IDs
#
.
Also, if a scan was not performed after the storage system microcode
was changed, perform a scan.
#
Path group IDs can be used for storage systems for which IFType
is X'3333' or higher.
Some of the storage systems do not
support Path Group ID.
YKZ288E MSG
SC=36 RC=36
Table 43 List of messages (message ID YKZ29x)
Explanation and recommended actionsMessage textMessage ID
The FROMCU has exceeded the maximum number of control units that
are supported by storage system.
Specify the maximum supported number of control units or less.
FROMCU() exceeds number of CU
that storage system supported.
YKZ290E MSG
SC=48 RC=48
The log dataset is full.
ddd
Name of the log dataset that became full
If a log dataset name cannot be collected, * is displayed.
xxx (decimal number)
Command code for the command that was executing when the
log dataset became full
See the description for the command code in the YKZ201E mes-
sage.
yyy (string)
Maintenance information
The log dataset is full. (DSN=ddd,
cp=xxx:yyy)
YKZ291I CON SC=0
RC=0
The log dataset was switched.
YKLOGmm
Previous log dataset (YKLOG01 or YKLOG02)
YKLOGnn
New log dataset (YKLOG01 or YKLOG02)
jjj
Job name
xxx (decimal number)
Command code for the command that was executing when the
log dataset was switched
See the description for the command code in the YKZ201E mes-
sage.
yyy (string)
Maintenance information
The log dataset was switched.
(from=YKLOGmm, to=YKLOGnn,
job=jjj, cp=xxx:yyy)
YKZ292I CON SC=0
RC=0
The value specified for the &YKLOGPT system symbol is invalid. The
program continues processing while assuming LOGR.
Revise the value specified for the &YKLOGPT system symbol.
The specified value for the system
symbol &YKLOGPT is invalid.
YKZ293E MSG CON
SC=0 RC=0
Messages 193