HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Explanation and recommended actionsMessage textMessage ID
The command cannot be executed because an REXX write error
occurred.
If the nnn value is 32:
Expand the job execution area, and then re-execute the command.
If the nnn value is 40:
Check that the REXX program is running in the TSO/E environment,
and then re-execute the command.
If the nnn value is not 32 or 40:
Correct the configuration file (XML) and the values assigned to
the parameters.
If the error still exists after the above action has been taken, contact
your HP Technical Support or authorized service provider.
nnn (decimal number)
Return code from the OS's REXX variable access routine
name (string)
REXX variable name
value (string)
REXX variable value
xxx (decimal number)
Command code of the command that was executing when the
error occurred
See the command code description in the explanation of the
YKZ201E message.
yyy (string)
Maintenance information
# If this message is output while the YKLOAD command is being
executed, the RC is 44.
A REXX write error occurred. (return
code=nnn, name= name,
value=value, cmd=xxx, pos=yyy)
YKZ204E TSO
RC=40
#
The command cannot be executed because a parameter error occurred.
message-text (string)
Message text
xxx (decimal number)
Command code of the command that was executing when the
error occurred
See the command code description in the explanation of the
YKZ201E message.
yyy (string)
Maintenance information
A Parameter error occurred. (de-
tail=message-text, cmd=xxx,
pos=yyy)
YKZ205E TSO RC=0
Messages166