HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)

Explanation and recommended actionsMessage textMessage ID
The value specified in the GENID parameter is not in hexadecimal
format.
GENID() not valid hex
YKU008E MSG
SC=48
You cannot specify the ATTIME parameter and the DEVN parameter
at the same time.
Specify ATTIME() and DEVN() parm
exclusively
YKU009E MSG
SC=48
You cannot specify the ATTIME parameter and the VOLUNIT parameter
at the same time.
Specify ATTIME() and VOLUNIT
parm exclusively
YKU009E MSG
SC=48
Access to the REXX variable identified by name failed.
For details about the return code, see IKJCT441 in the TSO/E
Programming Services.
nnnn
Error code returned upon REXX access
REXX failure return code=nnnn
starting with variable name
YKU010E TSO
RC=40
The specified copy group attribute value is invalid for this command.
Correct the value and then re-execute the command.
name
REXX variable name
attribute-value
REXX variable value
Invalid Copy Group attribute name
YKU050E MSG
SC=36 RC=48 (at-
tribute-value)
The YKSUSPND command with the ATTIME parameter specified was
executed on a Continuous Access copy group. This parameter is invalid
on Continuous Access copy groups.
Re-execute the YKSUSPND command without specifying the ATTIME
parameter.
ATTIME parameter invalid for Con-
tinuous Access Copy Group
YKU054E MSG
SC=36 RC=48
The PURGE and DEVN parameters cannot be specified simultaneously
for a Continuous Access Journal copy group.
Specify PURGE and DEVN paramet-
er exclusively for CAJ Copy Group
YKU055E MSG
SC=48 RC=48
The PURGE and VOLUNIT parameters cannot be specified simultan-
eously for a Continuous Access Journal copy group.
Specify PURGE and VOLUNIT para-
meter exclusively for CAJ Copy
Group
YKU055E MSG
SC=48 RC=48
The DRAIN parameter cannot be specified for a Continuous Access
Journal copy group.
DRAIN parameter cannot be spe-
cified for CAJ Copy Group
YKU056E MSG
SC=48 RC=48
The YKSUSPND command was executed on a Continuous Access Journal
copy group with the ATTIME parameter or CANCEL parameter
specified. These parameters are invalid on Continuous Access Journal
copy groups.
Re-execute the YKSUSPND command without specifying the ATTIME
or CANCEL parameter.
ATTIME and CANCEL parameters
are invalid for CAJ Copy Group
YKU057E MSG
SC=36 RC=48
One or more devices in the 7700E storage system does not support
Continuous Access Asynchronous copy groups.
Check that the command can be executed on this copy group, and
then re-execute the command.
Some pairs in this group do not sup-
port CAA services.
YKU058E MSG
SC=36 RC=48
Messages 141