HP XP7 Smart Manager for Mainframe Messages (TK916-96002, May 2014)
Table Of Contents

Explanation and recommended actionsMessage textMessage ID
A command control address could not be assigned because the path
is already defined in another logical path, or because a list of command
control addresses could not be obtained.
CCA could not be assigned because
either the path is already defined in
another logical path, or the list of
CCA could not be retrieved.
YKM514E ISPF
The same serial number cannot be specified for both the primary and
secondary sides of the same logical path.
You cannot specify the same serial
number to the primary side and the
secondary side of the same logical
path.
YKM515E ISPF
The port errport is already defined as portdir.
errport
The port that you specified
portdir
The port that is already defined
Port errport is already defined as
portdir port.
YKM516E ISPF
The value of PathID exceeds the maximum for this model.
The value of PathID exceeds the
value that is allowed in this Model.
YKM517E ISPF
The number of ports exceeds the maximum number for this composition.
errport
The port that you specified
Port errport exceeds the limit that
is allowed in this composition.
YKM518E ISPF
The path ID that is different for the primary site and for the secondary
site cannot be specified to the inter-disk controller logical path.
Different PathIDs cannot be specified
for the primary side and secondary
side of an inter-DKC path.
YKM519E ISPF
The device number or storage system serial number has not yet been
scanned in the device address domain ID.
remdevn
The device number you specified
remsn
The storage system serial number you specified
remdad
The device address domain ID you specified
These device number remdevn or
storage system S/N remsn are not
discovered on Device Address Do-
main remdad.
YKM520E ISPF
The exit operation cannot be performed until you define a command
device.
You cannot exit this panel until you
define a command device.
YKM521E ISPF
Enter the necessary information.
Please supply the required informa-
tion.
YKM522E ISPF
The License Key Dataset Name and Key Code fields cannot be specified
simultaneously.
You cannot enter values to both Li-
cense Key Dataset Name field and
Key Code field at the same time.
YKM523E ISPF
The value specified in the Key Code field contains characters that are
not numbers or letters.
Please enter alphanumeric characters
to Key Code field.
YKM524E ISPF
The key code is incorrect. Please re-enter the key code.
Invalid Key Code is entered. Please
re-enter the Key Code.
YKM525E ISPF
An incorrect dataset name is specified.Invalid dataset name is specified.YKM526E ISPF
Messages 119