HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

Format
hdvmcli [URL] AddPHSDToPRPU [options]
model=model serialnum=serial-number
rpuid=physical-resource-group-ID
{port=port-number|portname=port-name} domain=domain-ID
Parameters
Table 31 AddPHSDToPRPU command parameters
DescriptionStatusParameter name
Serial number of the storage systemRequired
serialnum
Model of the storage systemRequired
model
Specify the resource group ID of the physical resource group at
the registration destination.
Required
rpuid
Port number of the host storage domain that belongs to the
physical resource group
Specify either port or portname. Do not specify both
parameters at the same time. If they are specified at the same
time, an error occurs.
Optional
port
Port name of the host storage domain that belongs to the physical
resource group
Specify either port or portname. Do not specify both
parameters at the same time. If they are specified at the same
time, an error occurs.
Optional
portname
Domain ID of the host storage domain that belongs to the physical
resource group
This parameter can be specified in decimal and hexadecimal. If
you specify a hexadecimal number, add the 0x prefix.
The execution results are output in decimal.
Required
domain
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
rpuid
Obtain this value from the execution results of the GetStorageArray (subtarget=PResource-
PartitionUnit) command. Execute this command by specifying only the model and serial-
num parameters, and PResourcePartitionUnit for the subtarget parameter. In the exe-
cution results of this command, the required resourcePartitionUnitID value appears under
An instance of PResourcePartitionUnit. Use this value to specify the rpuid parameter.
port and domain
Obtain these values from the execution result of the GetStorageArray (subtarget=Host-
StorageDomain) command. Execute this command by specifying only the model and serial-
CLI Reference Guide 95