HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

DescriptionStatusParameter name
LU device number
For HP XP7, P9500 and XP24000/XP20000:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format ww:xx:yy, where
ww is the LDKC number, xx is the CU number, and yy is the
LDEV number. ww is optional. If ww is omitted, LDKC is as-
sumed to be 0.
For XP12000/XP10000/SVS200 and XP1024/XP128:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format xx:yy, where xx is
the CU number, and yy is the LDEV number.
If omitted, the number is automatically generated.
The execution results are output in decimal.
Optional
devnum
If set to LDEV, return the information on LDEV(s) related to the LU.
The value you can specify is LDEV only, which is not
case-sensitive.
Optional
lusubinfo
Format status of LDEVs that constitute an LU
You can specify the following values:
none: Creates an unformatted LDEV.
normal: Creates a formatted LDEV.
quick: Creates an LDEV formatted by using Quick Format.
If omitted, a formatted LDEV is created.
If you specify this value, make sure that the value of the
autoFormatLU attribute of the StorageArray instance is 0.
You can specify quick only for HP XP7, P9500, and
XP24000/XP20000 whose microcode version is 60-02-4 X-XX/XX
or later. During Quick Format, the load might become
concentrated on some components and the I/O performance of
all hosts that are running in the target storage system might be
lowered. For details about notes on performing Quick Format,
see the manual HP XP7 Command View Advanced Edition User
Guide.
Optional
(HP XP7
P9500
XP24000
XP20000
XP12000
XP10000
SVS200)
format
The unit for the value specified in the capacity parameter
The values you can specify are KB or block.
If this parameter is omitted, KB is set as the unit.
block can be specified for HP XP7, P9500, XP24000/XP20000,
and XP12000/XP10000/SVS200 only.
Optional
capacitytype
#
For HP XP7, P9500, and XP24000/XP20000, if you do not specify the fsindex and creation-
option parameters, you can optimize the regions of unused capacity to create an LU.
Parameter values to obtain in advance
serialnum and model
Command reference86