P9500HP XP7DescriptionValues
----YY
Support Page Reclamation for
Linux
Specify this value when the Page
Reclamation functionality is used
from an environment connected
to a Linux host.
68
----Y--
Online LUSE expansion
Specify this value when the
expansion of the capacity of a
LUSE volume is notified for a
host.
69
----YY
Change the Unit Attention for
Blocked Pool-VOLs
Specify this value when a Unit
Attention (UA) response for a
closed pool volume is changed
from NOT READY to MEDIUM
ERROR.
71
----YY
AIX GPFS Support
Specify this value when a
General Parallel File System
(GPFS) is used while connected
to an AIX host.
72
----YY
Support Option for WS2012
Specify this value when the Thin
Provisioning functionality is used
from an environment connected
to a Windows Server 2012 host.
When Windows Server 2012
ODX (Offload Data Transfer) is
used, specify this parameter if the
host mode is set to Windows or
Windows Extension.
73
Legend:
Y: The value can be specified.
--: The value cannot be specified.
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
port and domain
Command reference78