HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

XP12000/
XP10000/
SVS200
XP24000/
XP20000
P9500HP XP7DescriptionValues
--YYY
ESAM Response Change
Specify this value when the host
mode is set to Windows (mode
0C), Windows Extension
(mode 2C), VMware (mode 01),
or VMwares Extension (mode
21) in a configuration that uses
External Storage Access
Manager.
57
--YYY
LUN0 Change Guard
Specify this value when you use
HP-UX 11.31 and when you want
to prevent LUN0 from being
added or deleted.
60
----Y--
Expanded Persistent Reserve Key
Specify this value when 128 keys
are insufficient for the host.
61
----YY
Support option for vStorage APIs
based on T10 standards
Specify this value when a
connection to VMware ESXi 5.0
is established and VAAI, which
complies with the T10, is used.
63
----Y--
Round Trip Extended Set Up
Option
Specify this value to adjust the
host I/O response time when a
connection to a Continuous
Access pair is established and
the host mode option 51 is used.
For example, to use a
configuration that uses the
maximum number of processor
blades, combine this option and
the host mode option 51.
65
----YY
Change of the ED_TOV value
Specify this value if the OPEN
Fibre Channel Port configuration
meets the following conditions:
Topology is a direct Fibre
Channel connection
Port attribute (type) is Target
or RCU Target
67
CLI Reference Guide 77