HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)
XP12000/
XP10000/
SVS200
XP24000/
XP20000
P9500HP XP7DescriptionValues
YYYY
No display for ghost LUN
Specify this value when both of
the following conditions are
satisfied:
• The host mode is set to HP
(mode 03).
• You want to prevent devices
to which no paths have been
defined from creating a
device file when the HP-UX
host is connected.
12
YYYY
SIM report at link failure
Specify this value when you want
to get a SIM notification when the
number of unsuccessful
connections between ports
exceeds a threshold.
13
YYYY
HP TruCluster with Continuous
Access function
Specify this value when both of
the following conditions are
satisfied:
• The host mode is set to Tru64
(mode 07).
• You want to use TruCluster to
set up a cluster on both the
primary and secondary
volumes for Continuous Ac-
cess.
14
YYYY
HACMP
Specify this value when both of
the following conditions are
satisfied:
• The host mode is set to AIX
(mode 0F).
• HACMP 4.5 4.5.13 or later,
HACMP 5.1 5.1.0.4 or later,
or HACMP 5.2 or later is in
use.
15
Y------
VMware
Specify this value to register a
host on which VMware is running
in a host group.
19
CLI Reference Guide 73