HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

For details, see the documentation for the LUN management product for the storage system you are
using.
Table 26 Values that can be specified in the hostmodeoption parameter
XP12000/
XP10000/
SVS200
XP24000/
XP20000
P9500HP XP7DescriptionValues
YYYY
VERITAS Database
Edition/Advanced Cluster
Specify this value when using
VERITAS Database
Edition/Advanced Cluster for
Real Application Clusters or
VERITAS Cluster Server 4.0 or
later (I/O fencing feature).
2
YYYY
TPRLO
Specify this value when all of the
following conditions are satisfied:
The host mode is set to Win-
dows (mode 0C) or Windows
Extension (mode 2C).
An Emulex host bus adapter
is in use.
A mini-port driver is in use.
The TPRLO parameter for the
mini-port driver of the host bus
adapter is set to 2.
6
YYYY
Automatic recognition function of
LUN
Specify this value when both of
the following conditions are
satisfied:
The host mode is set to
Standard (mode 00) or
Solaris (mode 09).
You want to let the system
automatically recognize the
reduction and increase in the
number of devices when a
SUN host bus adapter is in
use.
7
Command reference72