HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

DescriptionAttribute
Copy type
BusinessCopy: Business Copy
ContinuousAccessSync: Continuous Access Synchronous
ContinuousAccessAsync: Continuous Access Asynchronous
Snapshot: Snapshot
FastSnap: Fast Snap
ContinuousAccessJournal: Continuous Access Journal
replicationFunction
Fence level of the P-VOL (example: Data)fenceLevel
Copy status
-1: Unknown
0: Simplex
1: Pair
8: Copying
9: Reverse-Copying
16: Split
17: Error
18: Error in LUSE
24: Suspending
25: Deleting
status
MU number of the P-VOL
-1 is output if the MU number is unknown.
This information is invalid for Continuous Access Synchronous and Continuous
Access Asynchronous.
muNumber
Copy pace
-1 is output for unknown or Continuous Access Journal.
copyTrackSize
Time when the S-VOL image is created by using the replication function
The number of seconds elapsed from 00:00:00 on January 1, 1970, is output
(the time setting is the storage system setting, not GMT).
This item is valid when the copy type is Snapshot or Fast Snap.
When the copy type differs from Snapshot, -1 is output.
splitTime
Device number of the P-VOL
For HP XP7, P9500, or XP24000/XP20000:
The value is output in the ww:xx:yy format, where ww is the logical DKC
number, xx is the CU number, and yy is the LDEV number.
For XP12000/XP10000/SVS200 or XP1024/XP128:
The value is output in the xx:yy format, where xx is the CU number and yy
is the LDEV number.
displayPvolDevNum
Output items480