HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)
DescriptionStatusParameter name
Device number of the P-VOL
For HP XP7, P9500, and XP24000/XP20000:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format ww:xx:yy, where
ww is the LDKC number, xx is the CU number, and yy is the
LDEV number. ww is optional. If ww is omitted, LDKC is as-
sumed to be 0.
For XP12000/XP10000/SVS200:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format xx:yy, where xx is
the CU number, and yy is the LDEV number.
The execution results are output in decimal.
Required
pvoldevnum
Port ID in the HORCM configuration file that manages the P-VOL
paths
If you specify this parameter, specify either pvolportid or
pvolportname. Do not specify both parameters at the same
time. If they are specified at the same time, an error occurs.
Optional
pvolportid
Port name in the HORCM configuration file managing the P-VOL
path
If you specify this parameter, specify either pvolportid or
pvolportname. Do not specify both parameters at the same
time. If they are specified at the same time, an error occurs.
Optional
pvolportname
Pool ID of the pool in which the differential data and journal data
for the P-VOL is to be stored
For Snapshot:
You must specify this parameter.
For Continuous Access Asynchronous:
You must specify this parameter.
For Continuous Access Journal:
You must specify this parameter when you are using method
2 or 3.
For other cases, this parameter value is invalid even if you specify
a value.
Optional
pvolpoolid
Serial number of the storage system in the HORCM configuration
file that manages the P-VOL.
To define a copy pair configuration by using a virtual ID, specify
a virtual serial number.
The confpvolserialnum and confpvoldevnum parameters
must be specified at the same time.
Optional
(HP XP7)
confpvolserial-
num