HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)
DescriptionStatusParameter name
Tiering policy to be applied to Smart volumes.
• 0: Level 0 (places the data in all tiers)
• 1: Level 1 (places the data preferentially in Tier 1)
• 2: Level 2 (places the data in both tiers when there are
two tiers, and preferentially in Tiers 1 and 2 when there
are three tiers)
• 3: Level 3 (places the data in both tiers when there are
two tiers, and preferentially in Tier 2 when there are three
tiers)
• 4: Level 4 (places the data in both tiers when there are
two tiers, and preferentially in Tiers 2 and 3 when there
are three tiers)
• 5: Level 5 (places the data preferentially in Tier 2 when
there are two tiers, and preferentially in Tier 3 when there
are three tiers)
• 6 to 31: Tiering policies 6 to 31
Tiering policies 6 to 31 can be modified by using the
ModifyTieringPolicy command.
For details about setting tiering policies 6 to 31, see Table
93.
Specify the policyID value output by the TieringPolicy
instance for this parameter.
The values that can be specified vary depending on the
storage system model and the microcode version.
HP XP7: 0 to 31
P9500 (microcode version 70-02-50-00/00 or later)
• If the microcode version is 70-02-50-XX/XX or later, or
is earlier than 70-03-00-XX/XX: 0, 1, or 5 can be spe-
cified.
If you specify a value from 2 to 4, the data is placed in
all tiers.
• If the microcode version is 70-03-00-XX/XX or later, or
is earlier than 70-05-00-XX/XX: 0 to 5 can be specified.
• If the microcode version is 70-05-00-XX/XX or later: 0
to 31 can be specified.
Optional
(HP XP7
P9500)
tieringpolicy
Specify whether to subject Smart volumes to hardware tier
relocation.
Either of the following values can be specified:
• enable: Subject to hardware tier relocation
• disable: Not subject to hardware tier relocation
Optional
(HP XP7
P9500)
tierrelocation
Unit of the value specified in the capacity parameter.
You can specify either KB or block.
If this parameter is omitted, KB is set.
Optional
(HP XP7
P9500)
capacitytype
CLI Reference Guide 291