HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)
DescriptionStatusParameter name
New transmission speed for a Fibre Channel connection to a port
• 0: Automatic
• 1: 1 Gbps
• 2: 2 Gbps
• 4: 4 Gbps
• 8: 8 Gbps
• 16: 16Gbps
The specifiable values depend on the storage system.
• HP XP7: 0, 2, 4, 8, 16
16 (16 Gbps) can be specified only when the value of the
topology parameter is Fabric(on), Point-to-Point.
• For P9500 and XP24000/XP20000: 0, 1, 2, 4, 8
• For XP12000/XP10000/SVS200: 0, 1, 2, 4
• For XP1024/ XP128: 0, 1, 2
Optional
channelspeed
#
New setting for LUN security enabled (either true or false)
Optional
lunsec
DomainID of the host storage domain
If you specify the nickname, newdomainnickname, hostmode,
hostmodeoption, wwn, wwnnickname or newwwnnickname
host storage domain attribute, you must also specify either the
domain or nickname parameter. Note that when this parameter
is specified, at least one host storage domain attribute must also
be specified. This parameter can be specified in decimal and
hexadecimal. If you specify a hexadecimal number, add the 0x
prefix.
The execution results are output in decimal.
If you specify the nickname, newdomainnickname, hostmode,
hostmodeoption, wwn, wwnnickname or newwwnnickname
host storage domain attribute, you must also specify either the
domain or nickname parameter. Note that when this parameter
is specified, at least one host storage domain attribute must also
be specified. This parameter can be specified in decimal and
hexadecimal. If you specify a hexadecimal number, add the 0x
prefix.
Optional
domain
Command reference276