HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

Format for XP1024/XP128
hdvmcli [URL] ModifyPort [options]
serialnum=serial-number model=model
{port=port-number|portname=port-name}
[topology=new-port-topology]
[fibreaddr=new-Fibre-Channel-address-for-the-port]
[channelspeed=new-transmission-speed-for-Fibre-Channel-connection-to-port]
[lunsec={true|false}] [domain=domain-ID]
[nickname={new-host-storage-domain-name|existing-host-storage-domain-name}]
[newdomainnickname=new-host-storage-domain-name]
[hostmode=host-mode-for-port]
[wwn=WWN wwnnickname=WWN nickname]
[wwn=WWN newwwnnickname=new-WWN-nickname]
[wwnnickname=WWN-nickname newwwnnickname=new-WWN-nickname]
Parameters
Table 90 ModifyPort command parameters
DescriptionStatusParameter name
Serial number of the port's storage systemRequired
serialnum
Model of the port's storage systemRequired
model
Number of the port
Specify either port or portname. Do not specify both
parameters at the same time. If they are specified at the same
time, an error occurs.
Optional
port
Port name
Specify either port or portname. Do not specify both
parameters at the same time. If they are specified at the same
time, an error occurs.
Optional
portname
New topology value for the port
Possible values are as follows.
For HP XP7, P9500, XP24000/XP20000,
XP12000/XP10000/SVS200, and XP1024/XP128:
Fabric(on), FC-AL
Fabric(off), FC-AL
Fabric(on), Point-to-Point
Fabric(off), Point-to-Point
Optional
topology
#
New Fibre Channel address for the port (the hex string represent-
ation)
Optional
fibreaddr
CLI Reference Guide 275