HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

remotePathGroupID=-1
pvolMngAreaPoolID=-1
svolMngAreaPoolID=-1
snapshotGroupID=1
confPvolSerialNumber=
confPvolDevNum=-1
confSvolSerialNumber=
confSvolDevNum=-1
*****: The values are encoded by the CLI.
GetStorageArray (subtarget=TieringPolicy)
GetStorageArray (subtarget=TieringPolicy) obtains information about tiering policies that
can be applied to Smart volumes of HP XP7 and P9500.
NOTE:
If the storage system is other than the following, valid values are not output to some attributes. For
details about output items, see TieringPolicy instance on page 494.
HP XP7
P9500 (with a microcode version of 70-05-00-XX/XX or later)
Parameters
Table 80 GetStorageArray (subtarget=TieringPolicy) command parameters
DescriptionStatusParameter name
Specify TieringPolicy.
Required
subtarget
Serial number of the storage system.
If you omit this parameter, all the storage systems become the
target.
Optional
serialnum
Model of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
model
Tiering policy ID for which information is to be obtained
If you specify this parameter, you must also specify the
serialnum and model parameters. If you specify this parameter
without specifying the serialnum and model parameters, the
information about all tiering policies in the storage system is
acquired.
For details about the values that can be specified, see the
description of the tieringpolicy parameter in the Table 94
.
If you omit this parameter, all the tiering policies become the
target.
Optional
policyid
CLI Reference Guide 241