HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)
objectID=*****
devNum=10
displayDevNum=00:0A
portID=23
portName=CL2-H
domainID=1
scsiID=15
LUN=10
wwnSecurityValidity=true
*****: The values are encoded by the CLI.
GetStorageArray (subtarget=LDEV)
GetStorageArray (subtarget=LDEV) obtains the information about LDEVs.
Parameters
Table 68 GetStorageArray (subtarget=LDEV) command parameters
DescriptionStatusParameter name
Specify LDEV.
Required
subtarget
Serial number of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
serialnum
Model of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
model
Device number of the LDEV that you intend to obtain
Specify this parameter when you want to obtain information about
a specific LDEV.
For HP XP7, P9500, and XP24000/XP20000:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format ww:xx:yy, where
ww is the LDKC number, xx is the CU number, and yy is the
LDEV number. ww is optional. If ww is omitted, LDKC is as-
sumed to be 0.
For XP12000/XP10000/SVS200 and XP1024/XP128:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format xx:yy, where xx is
the CU number, and yy is the LDEV number.
If you specify this parameter, you must also specify the model
and serialnum parameters. If you specify the model and
serialnum parameters, and omit the devnum parameter,
information about LDEVs in the specified storage system is
obtained.
The execution results are output in decimal.
Optional
devnum
CLI Reference Guide 197