HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006, May 2014)

Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
Command execution example 1
In this example, the GetStorageArray (subtarget=ArrayGroup) command obtains information
about parity groups in a storage system (serial number: 14010, model: XP12000).
hdvmcli GetStorageArray -o "D:\logs\GetStorageArray_ArrayGroup.log"
subtarget=ArrayGroup model=XP12000 serialnum=14010
Command execution result 1
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 20 ArrayGroup elements:
An instance of ArrayGroup
objectID=*****
chassis=1
number=0
displayName=1-1-1
raidType=RAID5(3D+1P)
emulation=OPEN-3
diskType=DKR2E-J146FC
diskSize=146
diskSizeInKB=153,092,096
formFactor=-1
controllerID=1
totalCapacity=418,184,640
allocatedCapacity=266,772,960
freeCapacity=149,008,320
autoLunCapacity=2,403,360
onDemandCapacity=0
totalFreeSpace=1,847,952
largestFreeSpace=1,847,952
substance=0
slprNumber=-1
clprNumber=-1
cuInfo=
openTotalCapacity=418,184,640
openAllocatedCapacity=266,772,960
openFreeCapacity=149,008,320
openAutoLunCapacity=2,403,360
openOnDemandCapacity=0
imTotalCapacity=0
imAllocatedCapacity=0
imFreeCapacity=0
imAutoLunCapacity=0
imOnDemandCapacity=0
mfTotalCapacity=0
mfAutoLunCapacity=0
Command reference180