Creating virtual storage machines
If you create a virtual storage machine, specify the model and serial number of a storage system that
actually exists.
Specifying an unassigned LDEV ID that has no volumes
An attempt to create a new volume for an unassigned LDEV ID that has no volumes by performing one
of following operations might result in an error:
Creating a new volume
Adding an LDEV ID to a resource group
Adding an LDEV ID to a virtual storage machine
One of the following errors might be generated:
KAIC5027-E
KAIC5721-E
KAIC6400-E
If this problem persists, the LDEV ID that was used might not be a number supported by the storage
system. Make sure that the LDEV ID is a supported number, then try again.
The value displayed for High Availability Manager
In Device Manager, High Availability Manager (HAM) pair information is displayed as follows:
In the Device Manager GUI, the copy type of a HAM pair primary or secondary volume is
displayed as "True Copy Sync".
In the Device Manager CLI, the pair information is displayed as "True Copy Sync" for
replicationFunction for a ReplicationGroup instance or ReplicationInfo instance.
Displaying the Ext. Storage Volume value in the parity group list
The Ext. Storage Volume value should be displayed as the base 10 LDEV ID of the external volume,
but it is displayed as the base 10 LDEV ID of the internal volume. To find the LDEV ID of the external
volume, see the Ext. Storage Volume value in the parity group list.*
* If the Ext. Storage Volume column is not displayed, click the Column Settings button and change the
settings on the screen so that the column is displayed.
The Detailed Information window displays incorrect drive type information
If an external storage system is connected and an external volume is mapped to an internal volume,
incorrect information for the drive type might appear in the Detailed Information window for the internal
volume.
The values displayed in the [CLPR] column in the Task Details window
If you open the Task Details window for Allocate Volumes or Allocate Like Volumes that were registered
in the Device Manager with a version earlier than 7.6.1, incorrect values might be displayed in the
[CLPR] column.
The display target for External Volumes tab in the External Storage window
When creating a path on a storage port that has LUN security disabled, available external volumes
are not displayed in the External Volumes tab.
To check the path setting for LUN security, execute the following CLI command: GetStorageArray
(subtarget=Port).