HP XP P9000 Tiered Storage Manager Software 7.6.1-02 Release Notes (TB585-96039, March 2014)
Table Of Contents
- HP XP P9000 Tiered Storage Manager Software 7.6.1-02 Release Notes
- Description
- Product models
- Devices supported
- Operating systems
- Enhancements
- Fixes
- Important considerations
- Filter conditions in the Create Tier dialog box and the Edit Tier dialog box
- Upgrading HP XP P9000 Command View Advanced Edition from 7.4.1 or earlier (in Windows)
- Temporary shortcut folder after installation or removal (in Windows)
- Specifying is not or <> in filter conditions
- Executing the GetFreeSpaces command for an SMI-S Enabled storage system
- Delay displaying the volume list when creating a Data Placement Profile
- Deletion of the logical group with data placement profiles
- Manage Data Placement Profiles (Logical Group View) dialog box
- Estimated time for the search inconsistency task (search inconsistent data placement profile task)
- Storage system links in the Mobility tab
- Migrating Mainframe THP volumes
- A tier created from the Device Manager GUI is not displayed in Tiered Storage Manager
- Editing a storage tier created by the CLI in the Edit Tier dialog box
- Message about refreshing the storage domain
- Mozilla 1.7.13 (HP-UX 11i v3) support
- Monitoring schedule templates
- Referencing (viewing) data migration tasks in Legacy mode
- Starting the migration wizard
- When an unexpected error (KAIC16009-E) occurs in the Migrate Data dialog box
- Executing a migration task in Legacy mode or by the Tiered Storage Manger CLI
- Data migration by using volumes that are applied data placement profiles
- Estimated time for data placement profile operations
- Stopping search inconsistency task (search inconsistent data placement profile task)
- Performance analysis
- Using XP P9000 Tiered Storage Manager CLI in a firewall environment
- Executing data migration
- KAIC05607-E or KAIC06400-E error during Migrate Data operation
- Selecting a tier when creating a migration plan
- Prerequisites
- Installation instructions
- Compatibility/interoperability
- Revision information
- Device Manager Software 7.6.1-02
- Replication Manager Software 7.6.1-02
- Tiered Storage Manager Software 7.6.1-02
Using XP P9000 Tiered Storage Manager CLI in a firewall environment
A KATS48000-E error message might occur when using the CLI interface on a client machine to
access an XP P9000 Tiered Storage Manager server under either of the following conditions:
• The client and the server are separated by a firewall
• You are using SSH communications between the client and the server
Note that if the Device Manager server uses the Windows operating system, this issue does not occur
when the following conditions are met:
• Windows firewall is enabled.
• Firewall exception of htsmService.exe is enabled.
Executing data migration
In the display window, check the task status and do the following:
• If the executed migration task is not displayed in the task list, execute the operation again. If the
error occurs repeatedly, try specifying conditions that decrease the number of volumes satisfying
those conditions.
• If the KAIC15001-E message is displayed when a Migration Task Details window of the executed
migration task is displayed, delete the migration task. Execute the operation again. If the error
occurs repeatedly, try specifying conditions that decrease the number of volumes satisfying those
conditions.
• If the Migration Task Details window of the executed migration task is displayed, it is not necessary
to make the migration plan again.
KAIC05607-E or KAIC06400-E error during Migrate Data operation
If the KAIC05607-E or KAIC06400-E error occurs during a Migrate Data operation, some of the
configuration changes might be applied to the storage system. Therefore, the content of the Task Status
displayed in the Migration pairs table on a Task Detail dialog of Migrate Data might not correspond
to the configuration of the storage system.
If this occurs, refresh the storage system information and check the current storage system configuration.
After that, perform the Migrate Data operation again by following the recent Task Status and the
configuration of the storage system.
Selecting a tier when creating a migration plan
Do not select a tier with more than 1,300 free volumes when creating a migration plan.
Prerequisites
Superseded version
7.6.0-00
Installation instructions
For details about installation requirements, see the HP XP P9000 Command View Advanced Edition
Suite Software Installation Guide.
Compatibility/interoperability
No issues.
Revision information
For this release, software and documentation revision levels are as follows:
Prerequisites 9