HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 Installation and Configuration Guide

+ value-for-Tiered-Storage-Manager
+ value-for-Replication-Manager
+ value-for-HiRDB
Other kernel parameters and shell restrictions:
kernel-parameter-value-to-be-set =
Max{
Max{
value-that-is-enabled-in-the-system
,
initial-value-of-the-OS
}
+ value-for-Common-Component
+ value-for-Device-Manager
+ value-for-Tiered-Storage-Manager
+ value-for-Replication-Manager
,
value-for-HiRDB
}
NOTE:
Max{x, y, z} indicates the maximum value among x, y, and z.
Related topics
About setting kernel parameters and shell restrictions (Linux), page 22
Recommended Red Hat Enterprise Linux 5 /etc/security/limits.conf values, page 25
Recommended Red Hat Enterprise Linux 6 /etc/security/limits.conf values, page 26
Modifying kernel parameter values and shell restrictions, page 32
Recommended Red Hat Enterprise Linux 5 /etc/security/limits.conf values
Before installing Command View AE Suite on a Red Hat Enterprise Linux system, set the shell restriction
values for the /etc/security/limits.conf file. Set the shell restrictions for soft and hard settings.
NOTE:
The soft value must be less than or equal to the hard value.
These settings depend on which Command View AE Suite products you are installing:
Common Component
Device Manager
Tiered Storage Manager
Replication Manager
Installation and Configuration Guide 25