HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 Installation and Configuration Guide

Common Com-
ponent
HiRDB
Operating Sys-
tem Initial
Value
Installer Check
value
Kernel Parameter
2621440026214400268435456730200320
kernel.shmall
Table 7 Kernel parameter values for Red Hat Enterprise Linux /etc/sysctl.conf (2/2)
Replication
Manager Soft-
ware
Tiered Storage
Manager Soft-
ware
Device Man-
ager
Kernel Parameter
512512129277
fs.file-max
3030162
kernel.threads-max
0044
kernel.msgmni
1110
4th parameter of kernel.sem
5050125
2nd parameter of kernel.sem
10000000050000000360349696
kernel.shmmax
00497
kernel.shmmni
100000000100695040477076480
kernel.shmall
These formulas are for calculating kernel parameter values:
For kernel.shmmax:
kernel-parameter-value-to-be-set =
Max{
Max{
value-that-is-enabled-in-the-system
,
initial-value-of-the-OS
}
,
value-for-Common-Component
+ value-for-Device-Manager
+ value-for-Tiered-Storage-Manager
+ value-for-Replication-Manager
,
value-for-HiRDB
}
For kernel.shmall:
kernel-parameter-value-to-be-set =
Max{
value-that-is-enabled-in-the-system
,
initial-value-of-the-OS
}
+ value-for-Common-Component
+ value-for-Device-Manager
HP StorageWorks P9000 Command View Advanced Edition Suite server installation24