HP XP P9000 Command View Advanced Edition Suite Software 7.6.0-00 CLI Reference Guide

GetStorageArray (subtarget=Port) , page 185
Table 140 Path instance attributes
DescriptionAttribute
Object ID of the path
objectID
Path name
This item is output if it has been registered.
name
Device number for identifying the logical unit
For P9500 or XP24000/XP20000, a combination of a logical DKC number, a
CU number, and an LDEV number
(=logical-DKC-number*65536+CU*256+LDEV) is output.
For XP12000/XP10000/SVS200 and XP1024/XP128, a combination of a CU
number and an LDEV number (=CU*256+LDEV) is output.
devNum
Port ID
portID
Domain ID of the host storage domain
domainID
SCSI ID
For Fibre Channel, 15 is output.
scsiID
LUN that is assigned to the path.
LUN
Indicates whether the WWN of the path and the WWN of the host storage domain
assigned to the path are the same.
true: Same
false: Not the same
wwnSecurityValidity
Port name
portName
Display name of the logical unit device number
For P9500 or XP24000/XP20000:
The value is output in the ww:xx:yy format, where ww is the logical DKC
number, xx is the CU number, and yy is the LDEV number.
For XP12000/XP10000/SVS200 or XP1024/XP128:
The value is output in the xx:yy format, where xx is the CU number and yy
is the LDEV number.
displayDevNum
PDEV instance
Commands for which a PDEV instance is output
AddPool, page 78
GetStorageArray (subtarget=ArrayGroup) , page 139
GetStorageArray (subtarget=PDEV) , page 176
GetStorageArray (subtarget=Pool) , page 178
Output items380