HP XP P9000 Command View Advanced Edition Suite Software 7.6.0-00 CLI Reference Guide

DescriptionAttribute
Pool ID of logical unit
One of the following values is output for P9500, XP24000/XP20000, or
XP12000/XP10000/SVS200:
When the logical unit is the P-VOL, S-VOL,or SP-VOL of Continuous Access
Journal Software: Pool ID of the pool used by the logical unit
When the logical unit is a pool volume: Pool ID of the pool to which the logical
unit has been assigned
In other cases, -1 is output.
journalPoolID
Type of the Thin Provisioning volume
One of the following values is output for P9500 or XP24000/XP20000:
-1: Non-THP/Smart volume
0: THP/Smart volume
1: THP/Smart pool volume
-1 is output for other storage systems.
thpType
Usage of on the THP/Smart volume (KB)
One of the following values is output for P9500 or XP24000/XP20000:
When the logical unit does not consist of THP/Smart volumes: The same value
as capacityInKB.
When the logical unit consists of THP/Smart volumes: Usage of on the
THP/Smart volumes.
-1 is output for other storage systems.
For P9500 or XP24000/XP20000, note the following points on the value that is
output for THP/Smart volume usage:
When the THP/Smart volumes are not assigned to a THP/Smart pool, 0 is
displayed.
When the operator is a partitioned storage manager, -1 is output.
Volume capacity is allocated from the logical unit in units of tens of megabytes,
so, when the usage rate of the logical unit reaches 100%, the value of con-
sumedCapacityInKB might not match the value of capacityInKB.
This value might increase significantly depending on the combination of the
file system and the OS of the host that is using the THP/Smart volumes. For
details, see the Thin Provisioning documentation.
consumedCapa-
cityInKB
Pool ID of the Thin Provisioning
One of the following values is output for P9500 or XP24000/XP20000:
When the logical unit consists of THP/Smart volumes: Pool ID of the THP/Smart
pool to which the THP/Smart volumes are assigned.
#1, #2
When the logical unit consists of THP/Smart pool volumes: Pool ID of the
THP/Smart pool that contains the THP/Smart pool volumes.
#2
For other volumes : -1 is output.
#1
When the THP/Smart volumes are not assigned to a THP/Smart pool, -1 is
displayed.
#2
When the operator is a partitioned storage administrator, -1 is displayed.
-1 is output for other storage systems.
thpPoolID
CLI Reference Guide 375