HP XP P9000 Command View Advanced Edition Suite Software 7.6.0-00 CLI Reference Guide

Parameters
Table 74 ModifyPort command parameters
DescriptionStatusParameter name
Serial number of the port's storage systemRequired
serialnum
Model of the port's storage systemRequired
model
Number of the port
Specify either port or portname. Do not specify both
parameters at the same time. If they are specified at the same
time, an error occurs.
Optional
port
Port name
Specify either port or portname. Do not specify both
parameters at the same time. If they are specified at the same
time, an error occurs.
Optional
portname
New topology value for the port
Possible values are as follows.
For P9500, XP24000/XP20000, XP12000/XP10000/SVS200,
and XP1024/XP128:
Fabric(on), FC-AL
Fabric(off), FC-AL
Fabric(on), Point-to-Point
Fabric(off), Point-to-Point
Optional
topology
#
New fibre channel address for the port (the hex string represent-
ation)
Optional
fibreaddr
New transmission speed for a Fibre Channel connection to a port
0: Automatic
1: 1 Gbps
2: 2 Gbps
4: 4 Gbps
8: 8 Gbps
The specifiable values depend on the storage system.
For P9500 and XP24000/XP20000: 0, 1, 2, 4, 8
For XP12000/XP10000/SVS200: 0, 1, 2, 4
For XP1024/ XP128: 0, 1, 2
Optional
channelspeed
#
New setting for LUN security enabled (either true or false)
Optional
lunsec
CLI Reference Guide 223