HP XP P9000 Command View Advanced Edition Suite Software 7.6.0-00 CLI Reference Guide
ModifyArrayReservation
ModifyArrayReservation extends the interval before the target storage system is unlocked.
Parameters
Table 69 ModifyArrayReservation command parameters
DescriptionStatusParameter name
Serial number of the storage systemRequired
serialnum
Model of the storage systemRequired
model
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
Command execution example
hdvmcli ModifyArrayReservation -o "D:\logs\ModifyArrayReservation.log"
"model=XP12000" "serialnum=14009"
Command execution result
An instance of ArrayReservation
objectID=*****
target=*****
serialNumber=14009
arrayType=XP12000
loginID=dmuser
beginTime=1,039,003,476
*****: The values are encoded by the CLI.
ModifyExternalTierRank
The ModifyExternalTierRank command changes the external LDEV tier rank, if the THP/Smart
pool volume is an external volume.
NOTE:
This command can only be used with P9500 with a microcode version of 70-04-00-XX/XX or later.
Command reference204